Brushless Motor Cycloidal Reducer Output Flange Design

Calculate tilting moment, spot hole conflicts and estimate thermal fit drift. Add supplier data for tilt and friction estimates, then prepare an interface review.

Published · Evidence checked · Preliminary engineering screen

Start the flange screen · Read the method

Output flange design screening calculator

Edit inputs for instant results. All defaults are illustrative. No bearing rating, fatigue life or standards conformity is verified.

1. Loads — required

Use concurrent peak load magnitudes, including your application impact allowance. The two moment magnitudes add conservatively. Ranges below are tool limits, not allowable design limits.

0–1000000

0–10000

0–1000000

0–10000

0.001–1000000

2. Flange geometry — required

Use the largest circular hole envelope at the section reviewed (thread, clearance hole or counterbore). Equal spacing assumed. Head, pilot, pin and tool-access clearances need a drawing review. Ranges below are tool limits, not allowable design limits.

25–300

0–299

1–299

1–40

3–24

3. Thermal fit scenario — required

Illustrative defaults: aluminum seat α = 23.4 and steel ring α = 11.2 µm/m·K, both +45°C. Replace with material data and separate measured temperatures; stator temperature is not bearing temperature. Ranges below are tool limits, not allowable design limits.

10–500

0–120

0–120

0–40

0–40

4. Supplier / joint data — optional

Leave unknown data blank. Stiffness must represent the installed assembly at the evaluated load. For friction, supply all three values; residual clamp must account for external loads, settlement and temperature. Radius comes from contact geometry, not bolt PCD. Ranges below are tool limits, not allowable design limits.

0.001–10000000 · Optional

0–1000 · Optional

0–1 · Optional

0.001–150 · Optional

Preliminary screen — engineering review required

Positive ligaments show no envelope overlap. They do not establish strength or a safe design.

Tilting moment
98.75 Nm
Angular tilt
Unknown — add stiffness
Bore-to-hole ligament
14.00 mm
Hole-to-edge ligament
9.50 mm
Adjacent hole gap
29.36 mm
Free diametral mismatch
41.17 µm
Friction torque estimate
Unknown — add joint data
Friction / peak torque
Unknown

Moment = (Fr × L + Fa × r) / 1000. Tilt needs installed stiffness. Thermal mismatch is seat minus ring free diameter growth: a positive value can loosen an outer-ring fit. Internal preload remains unknown.

Next: download the assumptions and request bearing / joint review.

OD: 75 mmBore: 16 mmPCD: 50 mm4 × Ø6 mmHole envelopes only — no strength assessment
Request interface & bearing reviewCalculation method & limits

1. Four decisions before releasing the flange

Separate interface size from load capacity

An ISO flange designation helps match tooling. Bearing, joint and flange strength require separate evidence.

ISO 9409-1:2004 — robot mechanical interface plates

Keep missing bearing data visible

Use the actual bearing model and installed stiffness before making a load, tilt or life decision.

THK — Cross-Roller Ring nominal life and load selection

Measure the fit through a thermal cycle

Model-specific fit guidance takes precedence over a generic preload or sleeve prescription.

THK — Cross-Roller Ring fit guidance

Use residual clamp in a slip estimate

A bolt proof or assembly load is not automatically the remaining clamp under service loads.

VDI 2230 Part 1:2015-11 — highly stressed bolted joints

2. Calculation method, assumptions and unknowns

The equations below are transparent screening relations. Zero loads are supported; empty required values and values outside the displayed tool ranges stop calculation. Optional fields remain unknown until supplied. Calculation is synchronous and runs locally.

Table 1. Reproducible screening equations
OutputEquationUnits and limits
Bending momentM = (Fr × L + Fa × r) / 1000N and mm → Nm; conservative sum of magnitudes; a vector load model may give a different resultant
Inner / outer ligament(PCD − hole − bore) / 2; (OD − PCD − hole) / 2mm; hole envelope only, no thread, stress or fatigue criterion
Adjacent hole gapPCD × sin(π / bolt count) − holemm; equally spaced centers; nonpositive gap is a conflict
Angular tiltθ = M / installed stiffnessNm / (Nm/mrad) → mrad; multiply by 206.264806 for arcsec
Friction torqueT = μ × bolt count × residual clamp × effective radiuskN × mm → Nm; one interface, uniform remaining clamp; no pin capacity added
Free thermal mismatchΔD = D × (α seat × ΔT seat − α ring × ΔT ring) / 1000D in mm, α in µm/m·K → µm; positive means seat grows more than ring
Unknown in every screen: bearing static capacity, fatigue life, contact stress, internal preload, flange stress, thread engagement, bolt fatigue and standards conformity. Obtain application-specific evidence before releasing a drawing.

3. Interface geometry: match drawings before assigning loads

A tooling interface and a reducer support bearing solve different problems. Match the mechanical interface on the mating drawing, then verify the support and joint against the load cases.

Table 2. Interface review checklist — no standard load ratings implied
FeatureReviewEvidence neededBoundary
Tooling interfacePCD, thread size/depth, pilot, pin position and clockingISO designation plus controlled mating drawingISO 9409-1 does not supply a bearing or joint rating
Bore and holesInner, outer and neighboring hole envelopesLargest envelope at every flange sectionPositive clearance alone does not establish fatigue strength
Fastener accessHead, washer, counterbore and wrench sweepAssembly tool model and section drawingTool calculation only covers the circular envelope entered
Locating featuresPilot fit and locating-pin strategyTolerance stack at cold and hot statesDo not assume two cylindrical pins share shear equally
ISO 9409-1:2004 — robot mechanical interface plates

4. Compare complete bearing support architectures

The following is a design comparison, not a ranking of interchangeable bearing sizes. Include the housing, retaining rings, mounting bolts and support span in a stiffness comparison.

Table 3. Bearing architecture tradeoffs
ArchitectureReason to considerMain uncertaintyNext step
Cross-roller ringCompact support for combined loadsModel-specific preload, fit, mounting-ring flexibility and installed stiffnessObtain load interaction and moment/deflection data
Back-to-back angular-contact pairUseful when axial span is availablePreload, pair spacing, contact angle and housing stiffnessCompare the complete supported assembly
Four-point contact bearingPotential compact alternativeContact transitions, moment capability and frictionRequire supplier approval for the load spectrum
Radial bearing plus separate thrust supportSeparates support functionsAssembly length, load sharing and alignmentEvaluate all support reactions together

No universal CC0 contact arc, stiffness multiplier or MPa stress is asserted. Use the selected manufacturer’s clearance designation and load-dependent curve.

THK — Cross-Roller Ring fit guidance

5. Distinguish output torque, bending moment and tilt

Bearing planeRadial force FrOverhang LAxial force FaOffset r = distance from shaft axis

Output torque acts about the shaft axis. Radial force at an axial overhang and axial force at a radial offset create bending about the bearing support. Supply all concurrent components to the reducer and bearing suppliers.

The screen adds the two bending magnitudes conservatively. For an actual load spectrum, resolve vectors and include acceleration, braking, impacts and changing arm orientation.

With supplied installed stiffness Cθ, θ = M / Cθ. A small-angle tool-tip contribution is approximately reach × θ in radians; add other compliance and positioning errors separately.

6. BLDC heat: model both sides of each fit

Seat: α seat × ΔT seatRing: α ring × ΔT ringFree diameter change ≠ installed roller clearance

Free thermal growth is a first comparison. Actual fit pressure depends on geometry, restraint, temperature gradients and tolerances. A seat that grows more than its steel outer ring may loosen the fit; it does not automatically squeeze the rollers.

Table 4. Thermal mechanisms and validation
ConditionPossible effectVerification
Seat grows more than outer ringOuter-ring fit may loosenMeasure both temperatures and hot fit; assess ring retention
Ring grows more than seatFit interference may increaseReview ring distortion and clearance with the bearing supplier
Inner ring is hotter than outer ringInternal clearance may changeModel the complete bearing, not just seat diameter
Steel sleeve in aluminum housingAdds a second fit and assembly operationCheck both interfaces, wall compliance and hot/cold retention; no universal H7/s6 prescription
THK — Cross-Roller Ring fit guidance

7. Bolting and dowels: keep load paths explicit

The friction estimate uses user-supplied minimum residual clamp and effective contact radius. It does not derive tightening torque from bolt size, add dowel strength or distribute external bending to individual fasteners. A ratio above one is an arithmetic comparison, not a safety factor.

For release, establish assembly scatter, embedment loss, thermal load changes, joint separation, transverse slip, bolt stress and thread stripping. A locating pin needs its own shear, bearing-pressure, fit and edge-distance checks; do not assume pins and friction reach their limits together.

VDI 2230 Part 1:2015-11 — highly stressed bolted joints

Prepare your drawing and screening report for review

8. Allocate runout and stiffness to a tool-point budget

Start with allowed tool-point error and reach. Allocate contributions to bearing tilt, housing deformation, flange runout, coupling alignment and control error. Define datums, measurement radius, mounting condition and temperature on the inspection plan.

A geometric tolerancing standard supplies a specification language; it does not set a universal 5 µm flange limit. Record radial and face runout traces through the intended rotation range, and measure loaded tilt separately. Flatness is a form tolerance and is specified without a datum reference.

9. Choose material and heat treatment as a manufacturing system

A steel flange can simplify bearing-seat compatibility; a lightweight alloy may reduce inertia while changing stiffness, wear, thread behavior and thermal fits. A sleeve or insert adds machining, retention and tolerance-stack costs. Compare complete part mass and process cost at the required life.

Specify grade, product condition, heat treatment, hardness depth where relevant, finish allowance and inspection sequence on the drawing. Use certified material properties. This guide does not equate regional grades or assign generic fatigue limits, anodize HRC values or medical/MRI suitability.

10. Make seals and hollow-bore routing part of the layout

Choose seals against speed, temperature, lubricant chemistry, ingress and friction targets using the exact seal datasheet. A V-ring is a contact element; a labyrinth plus V-ring assembly cannot be assumed to have zero drag or unlimited speed.

For cables, check the selected part’s dynamic bend radius, torsion rating, allowable moving length, connector envelope and shielding termination. A protocol such as EtherCAT does not define those mechanical limits. A service loop suits finite rotation; continuous rotation may require rotary electrical or pneumatic transfer.

Deburr and protect bore mouths, restrain the harness, then verify the complete motion envelope and life cycle. Do not infer a universal bore size from cable diameter alone.

11. Bearing life requires a selected bearing and duty cycle

The screen deliberately leaves bearing life unknown. Obtain the actual dynamic and static ratings, the manufacturer’s equivalent-load method, speed/oscillation conditions, preload and lubrication requirements. A C/P ratio is not a static safety factor.

Check peak-load indentation separately from rolling fatigue. A small-angle reversing actuator also needs an evaluation of fretting and lubricant replenishment. Changing the bearing pitch diameter alone cannot establish life or moment rigidity.

THK — Cross-Roller Ring nominal life and load selection

12. Risks, cost and scenario mismatch

Table 5. Decision risks and minimum mitigations
RiskConsequenceAction
Misuse: treating screening as approvalUnsupported bearing or flange strength decisionObtain combined-load ratings, stress/fatigue analysis and prototype evidence
Cost: demanding tight runout without a budgetExtra grinding, inspection and scrapAllocate tool-point error to each component before selecting drawing tolerances
Scene mismatch: small-angle reversing jointLubrication/fretting behavior differs from continuous rotationAsk the bearing supplier for oscillatory-duty evaluation
Joint slip or separationLost clamp, fretting and fastener fatigueVerify minimum service clamp, contact pressure and load distribution
Cable routing through rotating boreTwist accumulation, abrasion or connector interferenceUse the cable part datasheet, service loop, full-motion test or rotary transfer

These are review priorities, not a field-failure frequency dataset. Stop prototype operation when binding, unexpected current rise, slipping or excessive play occurs and inspect the assembly before increasing preload.

13. Release sequence and evidence checklist

ScreenSupplier dataVerifyPrototype
  1. Freeze interface revision and establish concurrent load cases and environment.
  2. Run this screen; resolve conflicts and list missing supplier data.
  3. Complete bearing, flange and joint analysis with reviewed assumptions.
  4. Build a prototype and record the measurements below against project limits.
Table 6. Acceptance evidence — limits must be project specific
CheckRecordAcceptance source
Runout and flatnessDatum scheme, radial/face measurement trace and temperatureProject drawing limits from tool-point error budget
Bearing behaviorInstalled moment/tilt curve, starting torque and load spectrumSelected bearing and assembly supplier limits
Thermal assemblySeat/ring temperatures, drag, current and fit through hot/cold cyclesProject limits after supplier review
Bolted jointTightening process, residual clamp, separation/slip and fatigue calculationApproved joint analysis and assembly procedure
Seals and cablesLeak/ingress test and full motion-cycle routing testSpecified environment, cable datasheet and service target

14. Worked examples with explicit assumptions

These are constructed calculations, not customer projects, measurements or validated product specifications.

Output flange screening calculator showing the constructed 98.75 Nm moment example and unknown supplier inputs
Original software execution capture, 2026-11-10. Reproduce with Reset defaults: Fr 750 N, L 120 mm, Fa 350 N, r 25 mm, peak torque 220 Nm; flange/bore/bolt-circle/hole diameters 75/16/50/6 mm, four bolts; seat diameter 75 mm, both temperature rises 45°C, expansion coefficients 23.4/11.2 µm/m·K. Optional supplier fields are blank. Moment is 98.75 Nm; thermal mismatch is +41.17 µm. This records software behavior, not hardware testing, customer results or design approval. Site navigation and floating contact controls are excluded from this calculator-only capture.

Illustrative wrist: resolve the moment first

Inputs: Fr = 750 N at L = 120 mm; Fa = 350 N at r = 25 mm.

Calculation: (750 × 120 + 350 × 25) / 1000 = 98.75 Nm.

Decision: Send 98.75 Nm and concurrent peak torque to the bearing supplier. If installed stiffness is supplied as 500 Nm/mrad, the linear estimate is 0.1975 mrad (40.74 arcsec). Neither value validates life.

Illustrative compact flange: detect a hole conflict

Inputs: OD = 75 mm; bore = 46 mm; PCD = 50 mm; hole envelope = 6 mm.

Calculation: (50 − 6 − 46) / 2 = −1 mm inner ligament.

Decision: The hole overlaps the bore. Revise bore, bolt circle or flange size before stress analysis. A larger OD alone does not fix this inner overlap.

Illustrative thermal comparison: distinguish radius and diameter

Inputs: D = 75 mm; α seat = 23.4, α ring = 11.2 µm/m·K; both rise 45°C.

Calculation: 75 × (23.4 × 45 − 11.2 × 45) / 1000 = 41.175 µm diametral mismatch.

Decision: The corresponding free radial difference is 20.5875 µm. This is not the bearing internal clearance change; restraint and thermal gradients need a separate model.

Reproduce a scenario in the calculator

15. Engineering decision FAQ

Using the screen

What result can I use immediately?

Use the load moment and hole-envelope clearances to prepare a design review. Optional stiffness and joint data add conditional estimates. The screen does not approve a design.

Why is angular tilt unknown by default?

Diameter does not establish installed stiffness. Supply a measured or vendor-supported assembly moment stiffness at the load of interest.

Does a positive ligament mean the flange is strong enough?

It only means the entered circular envelopes do not overlap. Flange thickness, stress concentration, thread engagement, material state and fatigue remain to be checked.

How are opposite load directions treated?

The tool adds moment magnitudes as a conservative scalar envelope. Use a vector load model for known directions and evaluate concurrent load cases, not unrelated independent peaks.

Interfaces and joints

Does ISO 9409-1 specify flange torque capacity?

No. Its public scope covers interface geometry, designation and marking and explicitly excludes correlation with load-carrying ranges. Use the actual robot, bearing and joint ratings.

Can I add friction torque and dowel shear capacities?

This tool does not add them. Load sharing depends on fit, contact compliance, slip sequence, pin bearing stress and joint geometry; verify a positive-drive design separately.

Where do residual clamp and effective radius come from?

Use minimum remaining clamp after service-load unloading, scatter, settlement and temperature effects. Derive effective friction radius from contact pressure and geometry. Neither comes automatically from bolt grade or bolt PCD.

Does a friction ratio over one prove joint safety?

No. It compares a conditional friction estimate with peak torque only. Combined shear, separation, contact pressure, fatigue and the required slip margin need joint analysis.

Thermal behavior and release

Can stator temperature substitute for ring temperature?

No. Use separate measured or modeled seat and ring temperatures at a common reference state. Heat paths and cooling can produce different rises.

Does an aluminum housing always squeeze the bearing?

No. Uniformly greater seat expansion can loosen an outer-ring fit. Internal preload depends on the complete temperature field, ring constraints and fits.

Is a steel sleeve always the right fix?

A sleeve changes two interfaces and their compliance. Compare its manufacturing and retention requirements with a different housing material, cooling or an independent support architecture.

What should I send for a detailed review?

Send a controlled interface drawing, concurrent load spectrum and duty cycle, bearing model/ratings/stiffness, material and temperature data, joint calculation, seal environment and cable part numbers.

16. Sources, evidence boundaries and review date

Published by Micro Cycloidal. Public source pages checked on . Standards abstracts establish scope; detailed dimension tables and full calculation procedures require the controlled standard or supplier document. The method table and worked examples are this page’s own screening calculations.

ISO 9409-1:2004 — robot mechanical interface plates

Public abstract: interface dimensions, designation and orientation; no load-capacity correlation.

Boundary: Confirm exact dimensions, thread depth, pilot and orientation against the controlled mating drawing and licensed standard. No torque or moment ratings are inferred here.

THK — Cross-Roller Ring nominal life and load selection

Manufacturer guidance: life uses the selected ring rating and equivalent load; preload, oscillation and lubrication affect applicability.

Boundary: No diameter-only load rating or universal life result is available. Ask THK about preload and small-angle oscillation.

THK — Cross-Roller Ring fit guidance

Fit recommendations differ by ring model, clearance class and rotating ring. THK warns about excessive preload from interference in CC0 assemblies.

Boundary: No universal steel-sleeve interference, preload percentage or contact stress is specified by this page.

VDI 2230 Part 1:2015-11 — highly stressed bolted joints

Publisher scope and FAQ: assembly scatter and preload losses must be considered when establishing minimum working clamp.

Boundary: This screen is not a complete VDI 2230 calculation. Bolt grade alone does not establish residual clamp or tightening torque.

Prepare an output flange interface review

Download your screening report and attach the drawing revision, concurrent load cases, duty cycle, bearing model, thermal data and assembly constraints. Request confirmation of scope and validation needs before release.

Inquiry Email

[email protected]

Include ratio, torque, backlash, interface drawings, quantity plan, and destination terms.

Instant Chat

WhatsApp Engineering Support

Use chat for quick routing; drawings and technical details can move to email.